PRIMUSr 1000 Integrated Avionics System
A28--1146--112--00
Engine Instrument and Crew Alerting System (EICAS)
5-34
Backup EICAS Display Failure Indications
Seefigure5--12foranillustrationofthefailureindicationsofthebackup
EICAS display.
D Failure of the RMU to display engine data is annunciated with
ENGINE DATA UNAVAILABLE.
D N
1
data failure is shown with a red X and removal of the pointer.
D Digital data failure is shown by amber dashes.
AD--50967@
RMU Backup Engine Display Failure Indication
Figure 5--12

Table of Contents