PRIMUSr 1000 Integrated Avionics System
A28--1146--112--00
Engine Instrument and Crew Alerting System (EICAS)
5-30
AD--50964@
EICAS Invalid Display Formats
Figure 5--9
EICAS Reversionary Modes
LOSS OF THE DISPLAY UNIT
Setting either pilots reversionary control panel MFD knob to EICAS
displays the EICAS on that sides MFD.
LOSS OF DISPLAY GUIDANCE COMPUTER (DGC) SYMBOL
GENERATOR
This is indicated by a red X on the EICAS display unit. Pushing the
pilots SG button on the reversionary control panel selects the other
symbol generator in DGC No. 2.