Actuate the oil pump by hand as shown in Table 6. Pull the hand lever
evenly as far as possible or press the pushbutton down as far as possible.
One actuation cycle corresponds to one stroke of the pump’s piston.
After actuation, you must reseal the supply tank tightly.
Maintenance instructions
Meter size:
Number of strokes:
Oil quantity
Oil
pump with lever
Pushbutton oil pump
1.6 ml
-
15
1.6 ml
-
15
DN 100
6 ml
15
-
DN 150
6 ml
6
-
DN 200
6 ml
6
-
DN 250
11 ml
11
-
DN 300
11 ml
11
-
DN 400
24 ml
24
-
DN 500
24 ml
24
-
DN 600
24 ml
24
-
Oil types
Oil type:
Operating
temperature range:
Klüber ISOFLEX PDP 38
-
25°C to +70°C
Table 5 | Maintenance instructions