EasyManua.ls Logo

Honeywell SM-RI-X

Honeywell SM-RI-X
198 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Honeywell
73024521a
© Elster GmbH | All rights reserved. Subject to modification
25
English
Actuate the oil pump by hand as shown in Table 6. Pull the hand lever
evenly as far as possible or press the pushbutton down as far as possible.
One actuation cycle corresponds to one stroke of the pump’s piston.
After actuation, you must reseal the supply tank tightly.
Maintenance instructions
Meter size:
Number of strokes:
Oil quantity
Oil
pump with lever
Pushbutton oil pump
1.6 ml
-
15
1.6 ml
-
15
DN 100
6 ml
15
-
DN 150
6 ml
6
-
DN 200
6 ml
6
-
DN 250
11 ml
11
-
DN 300
11 ml
11
-
DN 400
24 ml
24
-
DN 500
24 ml
24
-
DN 600
24 ml
24
-
Oil types
Oil type:
Operating
temperature range:
Klüber ISOFLEX PDP 38
-
25°C to +70°C
Table 5 | Maintenance instructions

Table of Contents

Related product manuals