33
English
5.2 Ambient conditions
Type:
SM
-
RI
-
X
Q75
Ambient temperature
-25°C to +70°C* -10°C to +70°C*
Storage temperature
-25°C to +70°C* -10°C to +70°C*
Humidity
0 to 80% RH
Max. height above sea level
2000 m
Outdoor installation
Yes
Mechanical environments
M1
Table 11 | Ambient conditions
* Temperature details for standard version. Restrict
ions possible, see type label.
5.3 Approvals
Approval:
Approv
al number:
Approval body:
MID
T10197
NMi Certin B.V.
Hugo de Grootplein 1
NL-3341 EG Dordrecht
PED
0038/PED/RQA660160
Lloyd’s Register | Verification Limited
71 Fenchurch Street
UK-EC3M 4BS London
ATEX
II 2G Ex h IIC T4 Gb
203104000-0411
DEKRA Certifi
cation B.V.
Meander 1051
NL-6825 MJ Arnheim
IECEx
Ex h IIC T4 Gb
IECEx TUR 16.0043x
TÜV Rheinland Industrieservice GmbH
Am Grauen Stein | 51105 Köln | Germany
Table 12 | Approvals
ATEX/IECEx legend:
Marking of explosion protection
II
Equipment group: industrial (mining excluded)
2
Equipment category 2 (Zone 1)
G
Potentially explosive gas atmospheres
h
Type of ignition protection: mechanical explosion protection
IIC
Explosion group for gases
T4
Temperature class
Gb
Equipment protection level