EasyManuals Logo

Honeywell Solaris 7980g User Manual

Honeywell Solaris 7980g
252 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #198 background imageLoading...
Page #198 background image
184 Solaris 7980g User Guide
Tag A 3 character case-insensitive field that identifies the desired menu
command group. For example, all RS232 configuration settings are
identified with a Tag of 232.
SubTag A 3 character case-insensitive field that identifies the desired menu
command within the tag group. For example, the SubTag for the
RS232 baud rate is BAD.
Data The new value for a menu setting, identified by the Tag and SubTag.
Storage A single character that specifies the storage table to which the com-
mand is applied. An exclamation point (!) performs the command’s
operation on the device’s volatile menu configuration table. A period
(.) performs the command’s operation on the device’s non-volatile
menu configuration table. Use the non-volatile table only for semi-
permanent changes you want saved through a power cycle.
Query Commands
Several special characters can be used to query the device about its settings.
^ What is the default value for the setting(s).
? What is the device’s current value for the setting(s).
* What is the range of possible values for the setting(s). (The device’s
response uses a dash (-) to indicate a continuous range of values. A
pipe (|) separates items in a list of non-continuous values.)
:Name: Field Usage (Optional)
This command returns the query information from the scanner.
Tag Field Usage
When a query is used in place of a Tag field, the query applies to the entire set of
commands available for the particular storage table indicated by the Storage field
of the command. In this case, the SubTag and Data fields should not be used
because they are ignored by the device.
SubTag Field Usage
When a query is used in place of a SubTag field, the query applies only to the sub-
set of commands available that match the Tag field. In this case, the Data field
should not be used because it is ignored by the device.
Data Field Usage
When a query is used in place of the Data field, the query applies only to the spe-
cific command identified by the Tag and SubTag fields.

Table of Contents

Other manuals for Honeywell Solaris 7980g

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Honeywell Solaris 7980g and is the answer not in the manual?

Honeywell Solaris 7980g Specifications

General IconGeneral
Input voltage100 - 240 V
Input frequency50 - 60 Hz
Power consumption400 mA
Power source typeAC
AC adapter output voltage5 - 5.2 V
USB version2.0
Standard interfacesKeyboard wedge, RS-232, USB
USB 2.0 ports quantity1
Connectivity technologyWired
Storage temperature (T-T)-20 - 60 °C
Operating temperature (T-T)0 - 40 °C
Operating relative humidity (H-H)5 - 95 %
CertificationCE, RoHS
Product colorBlack
LED indicatorsStatus
Housing material-
Programming functionYes
International Protection (IP) codeIPX5
Sustainability certificatesRoHS
TypeFixed bar code reader
Scanner type1D/2D
Maximum scan area0 x 190 mm
Yaw reading angle-75 - 75 °
Pitch reading angle-65 - 65 °
Light levels (direct sunlight)0 - 100000 lx
Linear (1D) barcodes supportedCodabar, Code 11, Code 128, Code 32, Code 39, Code 93, EAN-13, EAN-8, Intelligent Mail, JAN, MSI, PLANET, POSTNET, Plessey, Telepen, Trioptic, U.P.C.
2D (matrix & stacked) barcodes supportedAztec Code, Codablock, Code 49, Data Matrix, Han Xin, MaxiCode, Micro QR Code, PDF417, QR Code
Harmonized System (HS) code84716070
Weight and Dimensions IconWeight and Dimensions
Depth85 mm
Width152 mm
Height148 mm
Weight539 g

Related product manuals