Insert a character multiple times
F4 Send “xx” character “nn” times in the output message, leaving the cursor in the
current position. Syntax = F4xxnn where xx stands for the insert character’s hex
value for its ASCII code, and nn is the numeric value (00-99) for the number of times
it should be sent. Refer to the ASCII Conversion Chart (Code Page 1252), beginning
on page 224 for decimal, hex and character codes.
E9 and F4 Example: Send all but the last characters, followed by 2 tabs
Send all characters except for the last 8 from the bar code above, followed by 2
tabs.
Command string: E908F40902
E9 is the “Send all but the last characters” command
08 is the number of characters at the end to ignore
F4 is the “Insert a character multiple times” command
09 is the hex value for a horizontal tab
02 is the number of times the tab character is sent
The data is output as: 1234567890AB <tab><tab>
Insert a string
BA Send “ss” string of “nn” length in the output message, leaving the cursor in the
current position. Syntax = BAnnnns...s where nnnn stands for the length of the
string, and s...s stands for the string. The string is made up of hex values for the
characters in the string. Refer to the ASCII Conversion Chart (Code Page 1252),
beginning on page 224 for decimal, hex and character codes.
B9 and BA Example: Look for the string “AB” and insert 2 asterisks (**)
Using the bar code above, send all characters up to but not including “AB.” Insert 2
asterisks at that point, and send the rest of the data with a carriage return after.
Command string: B900024142BA00022A2AF10D
B9 is the “Send all characters up to a string” command
0002 is the length of the string (2 characters)
41 is the hex value for A
42 is the hex value for B

Table of Contents

Other manuals for Honeywell Solaris 7980g

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Honeywell Solaris 7980g and is the answer not in the manual?

Honeywell Solaris 7980g Specifications

General IconGeneral
Input voltage100 - 240 V
Input frequency50 - 60 Hz
Power consumption400 mA
Power source typeAC
AC adapter output voltage5 - 5.2 V
USB version2.0
Standard interfacesKeyboard wedge, RS-232, USB
USB 2.0 ports quantity1
Connectivity technologyWired
Storage temperature (T-T)-20 - 60 °C
Operating temperature (T-T)0 - 40 °C
Operating relative humidity (H-H)5 - 95 %
CertificationCE, RoHS
Product colorBlack
LED indicatorsStatus
Housing material-
Programming functionYes
International Protection (IP) codeIPX5
Sustainability certificatesRoHS
TypeFixed bar code reader
Scanner type1D/2D
Maximum scan area0 x 190 mm
Yaw reading angle-75 - 75 °
Pitch reading angle-65 - 65 °
Light levels (direct sunlight)0 - 100000 lx
Linear (1D) barcodes supportedCodabar, Code 11, Code 128, Code 32, Code 39, Code 93, EAN-13, EAN-8, Intelligent Mail, JAN, MSI, PLANET, POSTNET, Plessey, Telepen, Trioptic, U.P.C.
2D (matrix & stacked) barcodes supportedAztec Code, Codablock, Code 49, Data Matrix, Han Xin, MaxiCode, Micro QR Code, PDF417, QR Code
Harmonized System (HS) code84716070
Weight and Dimensions IconWeight and Dimensions
Depth85 mm
Width152 mm
Height148 mm
Weight539 g