SPM Flex Gas Detector
Network
The Ethernet mode can be set for either auto or manual� The Modbus TCP menu
can also be enabled or disabled (disabled is the default)� To enable the Ethernet
connection:
1. Connect the Ethernet cable to the detector’s connector (see “Connectors and
ports” on page 10).
2. Navigate to Main Menu > Set up > Network > Ethernet > Accept.
3. Select Mode > Auto > Accept > Accept. (Alternatively, instead of following the
Auto setup procedure, Enter Select Mode and scroll down to manually enter the IP
address, Subnet mask, and Default Gateway.)
4. To return to the Main menu, press Cancel twice.
The IP address can be found at Main menu > Review > Network Enter this
number in any browser to open the detector’s dedicated webpage:
Figure 28. Typical Ethernet web server screen
This web server screen displays details about the detector and its Chemcassette
cartridge� Faults and alarms can also be reset, a history of the detector’s activity
can be filtered and reviewed, and a graph of recent activity can be created and
exported�
The web server is designed for no more than ten simultaneous connections�
(Responses will be slower with more connections�)
NOTE

Other manuals for Honeywell SPM Flex

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Honeywell SPM Flex and is the answer not in the manual?

Honeywell SPM Flex Specifications

General IconGeneral
BrandHoneywell
ModelSPM Flex
CategorySecurity Sensors
LanguageEnglish

Related product manuals