CHAPTER 12: DESCRIPTION OF PARAMETER SETTINGS
63-4528—04 174
It is used to set rated power of the motor 1. The factory setting is the power of the drive
It is used to set the rated speed of the motor and need to set according to the value indicated on the motor nameplate.
It is used to set the number of motor poles (must be an even number).
Factory setting is 40% of the drive’s rated current.
It is used to set the rated speed of the motor and need to set according to the value indicated on the motor nameplate.
Pr. 05-06 and Pr.05-07 are used to record the motor operation time. They can be cleared by setting to 00 and time won’t be
recorded when it is less than 60 seconds
a
05 - 02 Rated Power of Induction Motor 1(kW)
Factory Setting: 0
Settings 0~655.35 kW
a
05 - 03 Rated Speed of Induction Motor 1 (rpm)
Factory Setting:
1710: 60Hz 4 poles
1410: 50Hz 4 poles
Settings 0~65535
05 - 04 Pole Number of Induction Motor 1
Factory Setting: 4
Settings 2~20
05 - 05 No-load Current of Induction Motor 1 (A)
Unit: Ampere
Factory Setting: 0
Settings 0 to the factory setting in Pr.05-01
Settings 0~65535
05 - 06 Accumulative Motor Operation Time (Min)
Factory Setting: 0
Settings 0~1439
05 - 07 Accumulative Motor Operation Time (Day)
Factory Setting: 0
Settings 00~1440