EasyManua.ls Logo

Honeywell VFD CORE

Honeywell VFD CORE
258 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
CHAPTER 12: DESCRIPTION OF PARAMETER SETTINGS
223 63-4528—04
09 - 28 CANopen Frequency Gain
Factory Setting: 100
Settings 0.00 ~ 200
09 - 29 CANopen Warning Record
Factory Setting: Read Only
Settings bit 0: CANopen Guarding Time out
bit 1: CANopen Heartbeat Time out
bit 2: CANopen SYNC Time out
bit 3: CANopen SDO Time out
bit 4: CANopen SDO buffer overflow
bit 5: Can Bus Off
bit 6: Error protocol of CANOPEN
09 - 30 CANopen Decoding Standard DS402
Factory Setting: 1
Settings 0: Communication definition of CP2000 series
1: CANopen Standard DS402 protocol
09 - 31 CANopen Status
Factory Setting: Read Only
Settings 0: Node Reset State
1: Com Reset State
2: Boot up State
3: Pre Operation State
4: Operation State
5: Stop State
09 - 32 CANopen Control Status
Factory Setting: Read Only
Settings 0: Not ready for use state
1: Inhibit start state
2: Ready to switch on state
3: Switched on state

Related product manuals