Program feature or option
Permitted in
UL864? Y/N
Possible settings
Settings permitted in UL 864
1
49 SU PPRESS TX SU PERV.
SOU N D
N
0 = disable
1 = enable
M ust be set to0” (disable).
1
53 DOWNLOAD CALLBACK
N
0 = callback r equir ed
1 = no callback r equi red
Must be set to0” (callback
r equ i r ed).
1
57 ENABLE 5800 RF BU TTON
GLOBAL ARM
N
0 = disable
1 = enable
M ust be set t o “0 (di sabl e).
1
58 ENABLE 5800 RF FORCE
ARM
N
0 = disable
1 = enable
M ust be set t o “0 (di sabl e).
1
60 ZONE 5/AUDIO ALARM
VER.
N
0 = disable
1 = enable
M ust be set t o “0 (di sabl e).
1
72 PRI N TER ON -L I NE MODE
N 0 = disable
1 = enable
N ot u sed. M u st be set t o 0 .
1
76 ACCESS RELAY #
(PARTI TION SPECIFIC)
N
01-96 = r elay number
00 = r el ay not u sed.
M ust be set t o “00 (r el ay n ot u sed)
for par t i t i on 1.
1
78 EXT. HOME CONTROL EVT
N 1 = ext en ded
0 = limited
N ot u sed. M u st be set t o 0 .
1
79 HOME CONTROL EVENTS
N 0 = disable
1 = enable
N ot u sed. M u st be set t o “ 0 i n each
ent r y.
1
80 L OG-FAULTS & RESTORES
N 0 = disable
1 = enable
N ot u sed. M u st be set t o 0 .
2
07 AUTO-DISARM DELAY
(PARTITION SPECIFIC)
N
00 = no del ay.
01-14 ti mes 4 mi nutes (04-56) delay.
15 = no auto disarming.
M
u
st be set t o “15 (no au t o
disarming) for par t it ion 1.
2
18 ENABLE GOTO FOR
PARTITION (PARTITION
SPECI FIC)
N
0 = disable
1 = enable
M ust be set t o “0 (di sabl e) for
par t it ion 1.
2*
21 SU PERVI SI ON PU L SES
FOR COMM UN I CATI ON S
DEVICE
N 0 = disable
1 = enable
N ot Used. Must be set t o00000”
(disable).
2
22 DISPLAY OTHER FIRE
ALARMS (PARTITION
SPECI FIC)
N
0 = disable
1 = enable
M ust be set t o “0 (di sabl e) for
par t it ion 1.
2
23 DISPLAY OTHER BURG &
PANIC (INCLUDING CO
ALARMS) (PARTITION
SPECI FIC)
N
0 = disable
1 = enable
M ust be set t o “0 (di sabl e) for
par t it ion 1.
2
24 DISPLAY TROUBLES OF
OTHER PARTITIONS
(PARTITION SPECIFIC)
N
0 = disable
1 = enable
M ust be set t o “0 (di sabl e) for
par t it ion 1.
3
01 EVENT DISPLAY LOCK
N
0 = disable
1 = enable
M ust be set to1” (enable).
3
12 ZN TYPE 18 DELAY USE
N
0 = disable
1 = enable
M ust be set t o “0 (di sabl e).
3
13 “SUPV ON OPEN AND
SH ORT (APPL I ES TO ZON E
TYPE 18
N 0 = T r oubl e on open /Su pv on shor t
1 = Supv on open/Supv on short
M ust be set t o “0.
3
14 W.F. ALARM SIL ENCE
OPT.
N
0 = Si l enced by U ser Code + OF F
1 = Si l enced wh en zone r est or es
M ust be set t o “0 (Si l en ced by U ser
Code + OFF).
3
16 ZON E TYP 17/18 DL Y
N
En t er 01-15 t i m es 2 seconds
En t er 00 for n o del ay
M ust be set t o 00 (no del ay).
3
18 EXTENDED DLY FOR TYP
17/18
N
0 = n o ext ended del ay
1 = mult iply delay by 4
M ust be set t o 0 (n o ext ended delay).
3
20 TRIG OUTS FUNC SEL
(ONLY APPLIES TO VISTA-
128FBPT)
N
0 = r emot e k eypad sounder
1 = keyswitch LEDs
M ust be set t o 0 (r em ot e k eypad
sounder ).
3
21 MAX ATEMPTS
Y
1-8
Must be set at 3, 4 or 5.