BASE
BASE
command
The BASE command sets the base in which symbols for the specified label
will be displayed in the symbol menu. It also specifies the base in which
the symbol offsets are displayed when symbols are used.
p’
Note
!b
BINary
is not available for labels with more than 20 bits assigned. In this
case the base will default to
HEXadecimaI.
Command Syntax:
:MACHine{
112):SYMBol:BASE
c
label-name
>,
c base-value
>
where:
c
label name
>
:: = string of up to 6 alphanumeric characters
c
base value
>
:: =
{BINary
)
HEXadecimal
1
OCTal
)
DECimal
1
ASCii)
Example:
OUTPUT
XXX;“:MACHINEl:SYMBOL:BASE
‘OATA’,HEXADECIMAL”