EasyManuals Logo

HP 5528A User Manual

HP 5528A
362 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #286 background imageLoading...
Page #286 background image
Message
Pl Error
P2 E
rror
P3
Error
PA
Error
Pr
Error
Sl
Error
Model
5528A
Errors and Error M
essa
ges
Ta
bl
e 1
7-1.
l aser
Measuremenr
Systcm Error Mcss<lges
(Con/inued)
Me
a
nin
g Ac
tion
Error in valuc from Material Te
m-
The oper
il
ling
temperat
ur
e of the material
perature
Se
n
so
r N
umber
1 temper
at
ure
se
n
so
r specified is
out
of
its
range,
or
there is a fault
in
the material
se
n-
Err
or in
va
lue from Material Tem-
so
r. Remo
ve
the bad sensor and verify that
perature
Se
nsor Number 2 the
error
co
ndition
goes away.
If
so,
ha
ve
it repaired. If
not
, the Displ
ay
ma
y need
Error in
va
lue from Material Tem-
servicing.
perature
Se
ns
or
Number
3
The
se
e
rror
s c
an
be cleared w
ithout
l
oss
of
measureme
nt
inform
at
i
on
by remov
ing
the
bad sensor.
Path
Error - Measurement Path
Mak
e s
ur
e the Beam strength meter on
the
return beam
ha
s been
interrup
ted. Meas
ur
e
ment
Displ
ay
point
s to the green
region over the
entire
length
of
the meas-
urement travel.
If
not
,
impro
ve the align-
m
en
t.
The beam mu
st
no
t be
broken
at
any
lime
during
Ih
e m
eas
urement
, and the B
ea
m
Strength meter must
not
p
oi
nt
into
the
red
region, or,
PA
Error will appear and
mea
s
ur
e-
ment data
will
be
lo
st.
This e
rror
c
an
o
nl
y be cleared by reselling
the Measurement Display, dnd results
in
a
l
oss
of
measurement dat
a.
Programming
error
The MC,
lS
urement
Display
ha
s re
ce
ived
an
HP-IU
command that II
do
e~
n
'
T
recognize,
or a mi
suse
of
an
allowed commdnd. Care-
fully check your programming instructions
and
ref
er
10 the Service
Manual
for
prop
er
sy
nt
ax
and application.
This
error
c
an
be cleared, wiThout
lo
ss
of
mea
su
reme
nt
data, by pre
ss
ing any key
on
the keyboard (except the R
ESET
kt!y).
Signal l
oss
error
.
May
in
di
cate
ra
te
Make
s
ur
e the o
pti
cs
do
no
t exceed I he
of
Opt
ic movement (
during
vc1o-
rated maximum
ve
lociti
es
s
hown
in th
is
User
's
cily
measuremen
t)
is
too
high
,
or
Guide, in each M
eas
ur
eme
nt
Sec
Tion
. Al
so
there is a problem in the meas
ur
e-
make sure the Be
am
Strength meter
on
the
ment path.
Mea
s
urement
Display
point
s to the
"g
r
een"
region over the entire length of the meas
ur
e-
ment travel.
If
nOI,
impr
ove the a
lignm
ent.
The Beam Strength meter must
nol
po
int
i
nto
the
red region
at
any t
im
e
durin
g a
measurement.
This
error
c
an
only
be cleared
by
resett
ing
the Displ
ay,
and r
es
ults in a l
os!>
of
meas
ur
e-
ment
data.
17-3

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the HP 5528A and is the answer not in the manual?

HP 5528A Specifications

General IconGeneral
BrandHP
Model5528A
CategoryMeasuring Instruments
LanguageEnglish

Related product manuals