36
Forwarding the packet with its precedence re-marked if the evaluation result is "conforming."
Priorities that can be re-marked include 802.1p priority, DSCP precedence, and local precedence.
GTS
GTS supports shaping the outbound traffic. GTS limits the outbound traffic rate by buffering exceeding
traffic. You can use GTS to adapt the traffic output rate on a device to the input traffic rate of its connected
device to avoid packet loss.
The differences between traffic policing and GTS are as follows:
Packets to be dropped with traffic policing are retained in a buffer or queue with GTS, as shown
in Figure 9. W
hen enough tokens are in the token bucket, the buffered packets are sent at an even
rate.
GTS can result in additional delay and traffic policing does not.
Figure 9 GTS
For example, in Figure 10, Device B performs traffic policing on packets from Device A and drops packets
exceeding the limit. To avoid packet loss, you can perform GTS on the outgoing interface of Device A so
that packets exceeding the limit are cached in Device A. Once resources are released, GTS takes out the
cached packets and sends them out.
Figure 10 GTS application
Line rate
Line rate supports rate-limiting the inbound traffic or the outbound traffic. The outbound traffic is taken for
example.
Device A
Device B
Physical link

Table of Contents

Other manuals for HP 5900

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the HP 5900 and is the answer not in the manual?

HP 5900 Specifications

General IconGeneral
ModelHP 5900
Rack MountableYes
MAC Address Table Size128K
Jumbo Frame SupportYes
Routing ProtocolOSPF, BGP, RIP, IS-IS, IGMP
Remote Management ProtocolSNMP, CLI
FeaturesQuality of Service (QoS), Jumbo Frames support, IPv4 support, IPv6 support
Operating Temperature0 °C to 45 °C
Operating Humidity10% to 90% non-condensing
Power SupplyInternal power supply - hot-plug / redundant

Related product manuals