Fabric OS 6.2 administrator guide 511
For more information on switch numbering, see the IBM publication FICON® Implementation Guide
(SG24-6497-00).
In the following sample IOCP configuration file, the UNIT value for FICON CUP definitions is 2032 for any
FICON director regardless of vendor or platform. All B-Series switches require UNIT=2032 for the CUP
definition. All Domain IDs are specified in hex values in the IOCP (and not in decimal values); the Domain
IDs in the example are for demonstration purposes only.
*------------------------------------------------------------------
* Brocade Domain_ID=61 (in hex)
*------------------------------------------------------------------
CNTLUNIT CUNUMBR=0D8,UNITADD=00,UNIT=2032,
PATH=(50,51),
LINK=(61FE,61FE)
IODEVICE ADDRESS=(0D8,1),CUNUMBR=0D8,UNIT=2032,STADET=Y,UNITADD=00
*---------------------------------------------------------------
CNTLUNIT CUNUMBR=0D9,UNITADD=00,UNIT=2032,
PATH=(8A,8B),
LINK=(22FE,22FE)
IODEVICE ADDRESS=(0D9,1),CUNUMBR=0D9,UNIT=2032,STADET=Y,UNITADD=00
*------------------------------------------------------------------
* Brocade Domain_ID=25 (in hex)
*------------------------------------------------------------------
*
CNTLUNIT CUNUMBR=0DB,UNITADD=00,UNIT=2032,
PATH=(5A,5B),
LINK=(25FE,25FE)
IODEVICE ADDRESS=(0DB,1),CUNUMBR=0DB,UNIT=2032,STADET=Y,UNITADD=00
*
*------------------------------------------------------------------