Hardware options installation 57
10.
Route and connect the drive cage bay 2 power cable (BP2) and the SAS cables to the drive cage
backplane.
11. Install the fan cage.
12. Install the air baffle.
13. Install the access panel.
14. Do one of the following:
o Close or install the tower bezel, as needed.
o Slide the server back into the rack.
CAUTION: To prevent improper cooling and thermal damage, do not operate the server unless
all bays are populated with either a component or a blank.
15. Install the hard drives and hard drive blanks.
16. Power up the server (on page 22).
Installing the eight-bay SFF drive cage (bay 3)
To configure this option for drive cage bay 3, locate the three jumper pins on the backplane. Move the
jumper from pins 1 and 2 to pins 2 and 3.
For more information, see "Drive cage jumper configuration settings (on page 21)."
1. Power down the server (on page 22).
2. Do one of the following:
o Open or remove the tower bezel, as needed ("Open or remove the tower bezel" on page 22).
o Extend the server from the rack (on page 24).
3. Remove the access panel (on page 25).
4. Remove the air baffle (on page 26).
5. Remove the fan cage (on page 26).
6. Remove the media bay blank (on page 27).