EasyManua.ls Logo

HP FlexFabric 5700 series - Page 152

HP FlexFabric 5700 series
185 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
145
[SwitchA-Ten-GigabitEthernet1/0/1] quit
# Configure interface Ten-GigabitEthernet 2/0/1 as a hybrid port.
[SwitchA] interface ten-gigabitethernet 2/0/1
[SwitchA-Ten-GigabitEthernet2/0/1] port link-type hybrid
# Assign Ten-GigabitEthernet 2/0/1 to VLAN 1001 as an untagged member.
[SwitchA-Ten-GigabitEthernet2/0/1] port hybrid vlan 1001 untagged
# Assign Ten-GigabitEthernet 2/0/1 to VLAN 4002 as a tagged member.
[SwitchA-Ten-GigabitEthernet2/0/1] port hybrid vlan 4002 tagged
# Set the PVID to VLAN 1001 for Ten-GigabitEthernet 2/0/1.
[SwitchA-Ten-GigabitEthernet2/0/1] port hybrid pvid vlan 1001
# Enable STP on Ten-GigabitEthernet 2/0/1.
[SwitchA-Ten-GigabitEthernet2/0/1] stp enable
[SwitchA-Ten-GigabitEthernet2/0/1] quit
# Configure interface Ten-GigabitEthernet 1/0/10 as a trunk port, and assign the interface to
VLAN 1001.
[SwitchA] interface ten-gigabitethernet 1/0/10
[SwitchA-Ten-GigabitEthernet1/0/10] port link-type trunk
[SwitchA-Ten-GigabitEthernet1/0/10] port trunk permit vlan 1001
# Enable STP on Ten-GigabitEthernet 1/0/10.
[SwitchA-Ten-GigabitEthernet1/0/10] stp enable
[SwitchA-Ten-GigabitEthernet1/0/10] quit
# Configure interface Ten-GigabitEthernet 2/0/10 as a trunk port, and assign the interface to
VLAN 1001.
[SwitchA] interface ten-gigabitethernet 2/0/10
[SwitchA-Ten-GigabitEthernet2/0/10] port link-type trunk
[SwitchA-Ten-GigabitEthernet2/0/10] port trunk permit vlan 1001
# Enable STP on Ten-GigabitEthernet 2/0/10.
[SwitchA-Ten-GigabitEthernet2/0/10] stp enable
[SwitchA-Ten-GigabitEthernet2/0/10] quit
# Create Layer 2 aggregate interface 1, and configure it to operate in dynamic aggregation
mode.
[SwitchA] interface bridge-aggregation 1
[SwitchA-Bridge-Aggregation1] link-aggregation mode dynamic
# Disable STP on Layer 2 aggregate interface 1.
[SwitchA-Bridge-Aggregation1] undo stp enable
[SwitchA-Bridge-Aggregation1] quit
# Assign ports Ten-GigabitEthernet 1/0/5 through Ten-GigabitEthernet 1/0/8 to Layer 2
aggregation group 1.
[SwitchA] interface ten-gigabitethernet 1/0/5
[SwitchA-Ten-GigabitEthernet1/0/5] port link-aggregation group 1
[SwitchA-Ten-GigabitEthernet1/0/5] quit
[SwitchA] interface ten-gigabitethernet 1/0/6
[SwitchA-Ten-GigabitEthernet1/0/6] port link-aggregation group 1
[SwitchA-Ten-GigabitEthernet1/0/6] quit
[SwitchA] interface ten-gigabitethernet 1/0/7
[SwitchA-Ten-GigabitEthernet1/0/7] port link-aggregation group 1

Table of Contents

Other manuals for HP FlexFabric 5700 series

Related product manuals