EasyManua.ls Logo

HP FlexFabric 5700 series - Page 158

HP FlexFabric 5700 series
185 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
151
Non-disruptive reconfiguration or isolating the switch may be performed. Continue?
[Y/N]:y
# Enable FSPF in VSAN 200.
[SwitchA-vsan200] fspf enable
[SwitchA-vsan200] quit
# Create interface VFC 1.
[SwitchA] interface vfc 1
# Configure the mode of VFC 1 as F.
[SwitchA-Vfc1] fc mode f
# Bind VFC 1 to interface Ten-GigabitEthernet 1/0/1.
[SwitchA-Vfc1] bind interface ten-gigabitethernet 1/0/1
# Assign VFC 1 to VSAN 100 as a trunk port.
[SwitchA-Vfc1] port trunk vsan 100
[SwitchA-Vfc1] quit
# Create interface VFC 2.
[SwitchA] interface vfc 2
# Configure the mode of VFC 2 as F.
[SwitchA-Vfc2] fc mode f
# Bind VFC 2 to interface Ten-GigabitEthernet 2/0/1.
[SwitchA-Vfc2] bind interface ten-gigabitethernet 2/0/1
# Assign VFC 2 to VSAN 200 as a trunk port.
[SwitchA-Vfc2] port trunk vsan 200
[SwitchA-Vfc2] quit
# Create interface VFC 10.
[SwitchA] interface vfc 10
# Configure the mode of VFC 10 as E.
[SwitchA-Vfc10] fc mode e
# Bind VFC 10 to Layer 2 aggregate interface 1.
[SwitchA-Vfc10] bind interface bridge-aggregation 1
# Assign VFC 10 to VSAN 100 as a trunk port.
[SwitchA-Vfc10] port trunk vsan 100
# Enable FSPF for VFC 10.
[SwitchA-Vfc10] undo fspf silent vsan 100
[SwitchA-Vfc10] quit
# Create interface VFC 11.
[SwitchA] interface vfc 11
# Configure the mode of VFC 11 as E.
[SwitchA-Vfc11] fc mode e
# Bind VFC 11 to Layer 2 aggregate interface 2.
[SwitchA-Vfc11] bind interface bridge-aggregation 2
# Assign VFC 11 to VSAN 200 as a trunk port.
[SwitchA-Vfc11] port trunk vsan 200
# Enable FSPF for VFC 11.
[SwitchA-Vfc11] undo fspf silent vsan 200

Table of Contents

Other manuals for HP FlexFabric 5700 series

Related product manuals