150
[SwitchA-Ten-GigabitEthernet1/0/1] qos wrr be group 1 byte-count 1
# Assign the other queues to the SP group on interface Ten-GigabitEthernet 1/0/1.
[SwitchA-Ten-GigabitEthernet1/0/1] qos wrr af2 group sp
[SwitchA-Ten-GigabitEthernet1/0/1] qos wrr af3 group sp
[SwitchA-Ten-GigabitEthernet1/0/1] qos wrr af4 group sp
[SwitchA-Ten-GigabitEthernet1/0/1] qos wrr ef group sp
[SwitchA-Ten-GigabitEthernet1/0/1] qos wrr cs6 group sp
[SwitchA-Ten-GigabitEthernet1/0/1] qos wrr cs7 group sp
[SwitchA-Ten-GigabitEthernet1/0/1] quit
# Enable byte-count WRR on interface Ten-GigabitEthernet 2/0/1.
[SwitchA] interface ten-gigabitethernet 2/0/1
[SwitchA-Ten-GigabitEthernet2/0/1] qos wrr byte-count
# Configure WRR on interface Ten-GigabitEthernet 2/0/1:
{ Assign 50% of the interface bandwidth to the FCoE traffic (traffic assigned to queue 1).
{ Assign 50% of the interface bandwidth to Ethernet data traffic (traffic assigned to queue 0).
[SwitchA-Ten-GigabitEthernet2/0/1] qos wrr af1 group 1 byte-count 1
[SwitchA-Ten-GigabitEthernet2/0/1] qos wrr be group 1 byte-count 1
# Assign the other queues to the SP group on interface Ten-GigabitEthernet 2/0/1.
[SwitchA-Ten-GigabitEthernet2/0/1] qos wrr af2 group sp
[SwitchA-Ten-GigabitEthernet2/0/1] qos wrr af3 group sp
[SwitchA-Ten-GigabitEthernet2/0/1] qos wrr af4 group sp
[SwitchA-Ten-GigabitEthernet2/0/1] qos wrr ef group sp
[SwitchA-Ten-GigabitEthernet2/0/1] qos wrr cs6 group sp
[SwitchA-Ten-GigabitEthernet2/0/1] qos wrr cs7 group sp
[SwitchA-Ten-GigabitEthernet2/0/1] quit
6. Configure FCoE:
# Configure the switch to operate in FCF mode.
[SwitchA] fcoe-mode fcf
# Create VSAN 100. Enable the fabric configuration feature in VSAN 100. By default, the fabric
configuration feature is enabled.
[SwitchA] vsan 100
[SwitchA-vsan100] domain configure enable
# Set the domain ID to 2 in VSAN 100.
[SwitchA-vsan100] domain-id 2 preferred
Non-disruptive reconfiguration or isolating the switch may be performed. Continue?
[Y/N]:y
# Enable FSPF in VSAN 100.
[SwitchA-vsan100] fspf enable
[SwitchA-vsan100] quit
# Create VSAN 200. Enable the fabric configuration feature for VSAN 200. By default, the fabric
configuration feature is enabled.
[SwitchA] vsan 200
[SwitchA-vsan200] domain configure enable
# Set the domain ID to 3 in VSAN 200.
[SwitchA-vsan200] domain-id 3 preferred

Table of Contents