Table 5-8 cpqacuxe Error Codes
ReasonErrorCode
Success
Success
0
Problem spawning ACU process (user is not authenticated to
use ACU or ACU is already running).
General error
1
Error opening capture file.
Failure opening capture file
'%s'
2866
Error opening input file.
Failure opening input file
'%s'
2867
Error opening error file.
Failure opening error file
'%s'
2868
The specified command is missing or in the incorrect place in
the file.
%s command expected
2869
The specified command is not a valid scripting command.
'%s' is not a supported
command
2870
The specified command does not belong in the Controller section
of the script file.
'%s' is not a Controller
command
2871
The specified command does not belong in the Array section of
the script file.
'%s' is not an Array command
2872
The specified command does not belong in the LogicalDrive
section of the script file.
'%s' is not a Logical Drive
command
2873
A command found in the HBA section is not a valid command
for this section.
%s' is not an HBA command
2874
The specified command is used more than once in the same
section. It should only be used once per section.
More than one '%s' command
cannot exist in the same
section
2875
No controllers were detected. This error applies to input mode
only.
No controllers detected
2821
Input mode cannot be run on internal controllers without slot
information online. For Windows, this means the System
Management Driver has to be loaded.
Slot information is not
available
1102
The controller specified is not specified correctly.
Controller '%s' is invalid
2819
The controller specified was not detected.
Could not detect Controller
'%s'
2820
Invalid Method value.
Invalid Method
2818
Invalid Controller value.
Invalid Controller
2819
The specified Read Cache/Write Cache Ratio is not supported
either by the controller or the current controller configuration.
Invalid Read Cache/Write
Cache Ratio
2822
The specified Rebuild Priority is not supported.
Invalid Rebuild Priority
2823
The specified Expand Priority is not supported. Also, this error
occurs if the controller does not allow expansion and therefore
does not support Expand Priority.
Invalid Expand Priority
2824
Invalid Surface Scan Delay
Invalid Surface Scan Delay
2857
The specified ClearConfigurationWithDataLoss parameter is not
correct.
Invalid
ClearConfigurationWithDataLoss
parameter
2849
The Array ID is invalid.
Invalid Array
2825
cpqacuxe 79

Table of Contents

Other manuals for HP Integrity rx1620

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the HP Integrity rx1620 and is the answer not in the manual?

HP Integrity rx1620 Specifications

General IconGeneral
BrandHP
ModelIntegrity rx1620
CategoryServer
LanguageEnglish

Related product manuals