EasyManuals Logo

HP MSA 2040 Troubleshooting Guide

HP MSA 2040
30 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #8 background imageLoading...
Page #8 background image
Table 2 LED Indications and recommended actions (continued)
Action RequiredCauseStatusIndicator
The enclosure rear panel
FRU OK LED
No action required. Wait for
system to boot.
System is functioning
properly. System is booting.
On; blinking regularly
Verify the following:The controller module is not
powered on. The controller
module has failed.
Off
The controller module is
fully inserted and latched
in place, and the
enclosure is powered on
The event log for specific
information regarding the
failure
No action required.System is functioning
properly.
OffThe enclosure rear panel
Fault/Service
Required LED
Amber; blinking regularly
Restart this controller
from the other controller
using the SMU or the CLI
Hardware-controlled
power-up error
Cache flush error
If the previous action
does not resolve the
Cache self-refresh error
fault, remove the
controller and reinsert it
If the previous actions do
not resolve the fault, contact
an authorized service
provider for assistance.
Replace the controller.
No action required.System is functioning
properly.
On; blinking regularlyConnected host port Host
Link Status LED
8 Troubleshooting HPE MSA 1040/2040 Storage