Table 2 LED Indications and recommended actions (continued)
Action RequiredCauseStatusIndicator
The link is down.Off
• Check cable connections
and reseat if necessary
• Inspect cables for
damage. Replace cable
if necessary
• Defective cable causes
fault. Swap cables to
determine the fault.
Replace cable if
necessary
• Verify that the switch, if
any, is operating
properly. If possible, test
with another port
• Verify that the HBA is
fully seated, and that the
PCI slot is powered on
and operational
• In the SMU, review event
logs for indicators of a
specific fault in a host
datapath component;
follow any
Recommended Actions.
• Contact an authorized
service provider for
assistance.
No action required.System is functioning
properly.
OnA connected port
Expansion Port
Status LED
The link is down.Off
• Check cable connections
and reseat if necessary
• Inspect cables for
damage. Replace cable
if necessary
• Defective cable causes
fault. Swap cables to
determine the fault.
Replace cable if
necessary
• In the SMU, review event
logs for indicators of a
specific fault in a host
datapath component;
follow any
Recommended Actions.
• Contact an authorized
service provider for
assistance
No action required.System is functioning
properly.
OnA connected port Network
Port Link Status LED
Use standard networking
troubleshooting procedures
The link is down.Off
to isolate faults on the
network.
Events and LEDs 9