Shutting down or bringing up an E1 line also shuts down or brings up the serial interface created
for it.
To shut down or bring up only the serial interface for an E3, unframed E1, or framed E1 channel,
use the shutdown or undo shutdown command in serial interface view.
To configure a CE3 interface in CE3 mode:
Step Command Remarks
1. Enter system view.
system-view N/A
2. Enter CE3 interface view.
controller e3 interface-number N/A
3. Configure the interface to
operate in CE3 mode.
using ce3
The default operating mode is CE3
mode.
4. (Optional.) Set the operating
mode of an E1 line on the CE3
interface to unframed mode or
framed mode.
Method 1:
Set the operating mode to
unframed (E1) mode:
e1 line-number unframed
Method 2:
Set the operating mode to
framed (CE1) mode and
bundle timeslots on the CE1
interface:
a. (Optional) undo e1
line-number unframed
b. e1 line-number
channel-set set-number
timeslot-list list
By default:
In method 1, the operating
mode is CE1.
In method 2, the operating
mode is framed, and no
channel sets are created.
5. (Optional.) Configure the
interface description.
description text
By default, the description of an
interface is interface-name
Interface.
6. (Optional.) Configure the CE3
interface to perform BERT test,
and configure the CE3
interface to perform BERT test
on an E1 channel created on
the interface.
bert pattern { 2^7 | 2^11 | 2^15
| qrss } time number [ unframed ]
e1 line-number bert pattern { 2^11
| 2^15 | 2^20 | 2^23 | qrss }
time number [ unframed ]
By default, no BERT test is
performed.
7. (Optional.) Set the clock
mode.
For the CE3 interface:
clock { master | slave }
For an E1 line:
e1 line-number set clock
{ master | slave }
The default mode for both the CE3
interface and E1 line is slave,
which is line clock.
8. (Optional.) Set the national
bit.
national-bit { 0 | 1 } The default is 1.
9. (Optional.) Enable loopback.
For the CE3 interface:
loopback { local | payload |
remote }
For an E1 line:
e1 line-number set loopback
{ local | remote | payload }
By default, loopback is disabled.
10. Set E1 framing format on an
E1 line.
e1 line-number set frame-format
{ crc4 | no-crc4 }
The default is no-crc4.
35

Table of Contents

Other manuals for HP MSR Router Series

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the HP MSR Router Series and is the answer not in the manual?

HP MSR Router Series Specifications

General IconGeneral
BrandHP
ModelMSR Router Series
CategoryNetwork Router
LanguageEnglish

Related product manuals