IPv6 Addressing Configuration
Duplicate Address Detection (DAD)
Operating Notes
A verified link-local unicast address must exist on a VLAN interface before
the switch can run DAD on other addresses associated with the interface.
If a previously configured unicast address is changed, a neighbor adver-
tisement (an all-nodes multicast message--ff02::1) is sent to notify other
devices on the VLAN and to perform duplicate address detection.
IPv6 addresses on a VLAN interface are assigned to multicast address
groups identified with well- known prefixes. For more on this topic, refer
to “Multicast Application to IPv6 Addressing” on page 3-21.
DAD is performed on all stateful, stateless, and statically configured
unicast addresses, but not on Anycast addresses.
Neighbor solicitations for DAD do not cause the neighbor cache of
neighboring switches to be updated.
If a previously configured unicast address is changed, a neighbor adver-
tisement is sent on the VLAN to notify other devices, and also for duplicate
address detection.
If DAD is disabled when an address is configured, the address is assumed
to be unique and is assigned to the interface.
4-20

Table of Contents

Other manuals for HP PROCURVE 2910AL

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the HP PROCURVE 2910AL and is the answer not in the manual?

HP PROCURVE 2910AL Specifications

General IconGeneral
ModelHP ProCurve 2910al
Switching Capacity128 Gbps
Throughput95.2 Mpps
ManagementWeb, CLI, SNMP
Jumbo Frame SupportYes
ManageableYes
Power100-240 VAC
Power SupplyInternal
Operating Temperature0°C to 45°C (32°F to 113°F)
StackingYes
MAC Address Table Size32000 entries
Routing ProtocolRIP, OSPF
FeaturesIPv6, VLAN, QoS, ACLs
Operating Humidity15% to 95% non-condensing
Uplink Ports4
Power over EthernetYes (PoE+ models available)