EasyManuals Logo
Home>HP>Switch>ProCurve Switch 212M

HP ProCurve Switch 212M User Manual

HP ProCurve Switch 212M
166 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #83 background imageLoading...
Page #83 background image
6-19
Configuring the Switch
Trap Receivers
Configuring the Switch
2. Press [E] (for E
dit). The cursor moves to the Send Authentication Traps field.
3. Press the Space bar to enable (Ye s ) or disable (No) sending authentication
traps, then press [>] or [Tab] to move the cursor to the Address field.
4. Type in the IP address of a network management station to which you
want the switch to send SNMP trap packets, then press [>] or [Tab] to move
the cursor to the Community field.
5. Type in the name of the SNMP community to which the network manage-
ment station belongs, then press [>] or [Tab] to move the cursor to the Events
field.
6. Press the Space bar to select the level of internal switch events that cause
trap packets to be sent:
7. Press [Enter], then press [S] (for S
ave) and return to the Switch Management
Access Configuration menu.
Event Level Description
None (default) Send no log messages.
All Send all log messages.
Not INFO Send the log messages that are not information-only.
Critical Send critical-level log messages.
Debug Reserved for HP-internal use.
Sraswb.book : SIER_SW6.FM Page 19 Tuesday, June 30, 1998 12:20 PM

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the HP ProCurve Switch 212M and is the answer not in the manual?

HP ProCurve Switch 212M Specifications

General IconGeneral
BrandHP
ModelProCurve Switch 212M
CategorySwitch
LanguageEnglish

Related product manuals