154 HP ProLiant DL380 Generation 3 Server User Guide
Environmental Specifications
Temperature range
Operating
10°C to 35°C (50°F to 95°F)
Shipping
-40°C to 70°C (-40°F to 158°F)
Maximum wet bulb
temperature
28°C (82.4°F)
NOTE: All temperature ratings shown are for sea level. An
altitude derating of 1°C per 300 m (1.8°F per 1,000 ft to
10,000 ft) is applicable. No direct sunlight allowed.
Relative humidity (noncondensing)
Operating 10% to 90%
Non-operating 5% to 95%
NOTE: Storage maximum humidity of 95% is based on a
maximum temperature of 45°C (113°F). Altitude maximum for
storage corresponds to a pressure minimum of 70 KPa.