Error messages 153
SCSI Port Y: Side-Panel must be Closed to Prevent Overheating
SCSI Port Y: Redundant Power Supply Malfunction Detected
SCSI Port Y: Wide SCSI Transfer Failed
SCSI Port Y: Interrupt Signal Inoperative
SCSI Port y: Unsupported ProLiant Storage System Detected
Audible Beeps: None
Possible Cause: Environment threshold was violated on the drive enclosure.
Action:
• Check the cooling fan operation by placing a hand over the fan.
• Be sure the internal plenum cooling fan in tower servers or storage systems is operational. If the fan is
not operating, check for obstructions and check all internal connections.
• Replace the unit side panel if removed.
• Check the LEDs. If the ProLiant Storage System power LED is amber instead of green, this indicates a
redundant power supply failure.
• If the message indicates to check SCSI cables, do the following:
a. Compare the cabling against the diagrams in the HP Smart Array Controller User Guide.
b. If the routing is correct, replace cables on the specified port until the POST error message is
eliminated.
1778-Drive Array Resuming Automatic Data Recovery Process
Audible Beeps: None
Possible Cause: A controller reset or power cycle occurred while Automatic Data Recovery was in progress.
Action: No action is required.
1779-Slot X Drive Array - Replacement drive(s) detected OR previously failed drive(s)
now operational:...
...Port Y: SCSI ID Z:
Restore data from backup if replacement drive X has been installed.
Audible Beeps: None
Possible Cause: More drives failed (or were replaced) than the fault-tolerance level allows. Unable to rebuild
array. If drives have not been replaced, this message indicates an intermittent drive failure.
Action: Be sure the system is always powered up and down correctly:
• When powering up the system, all external storage systems must be powered up before (or at the same
time as) the server.
• When powering down the system, the server must be powered down before powering down any
external storage systems.