EasyManua.ls Logo

HP ProLiant DL560 Gen10 - Installing Drive Cages

HP ProLiant DL560 Gen10
125 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
The Systems Insight Display module is shown.
Removing and replacing a PCIe riser cage
CAUTION:
To prevent damage to the server or expansion boards, power down the server and remove all AC power
cords before removing or installing the PCIe riser cage.
Procedure
1. Power down the server (Power down the server on page 33).
2. Remove all power:
a. Disconnect each power cord from the power source.
b. Disconnect each power cord from the server.
3. Do one of the following:
Extend the server from the rack (Extend the server from the rack on page 33).
Remove the server from the rack (Removing the server from the rack on page 34).
4. Remove the access panel (Removing the access panel on page 35).
5. Disconnect all cables attached to the expansion boards in the PCIe riser cage.
6. Remove the riser cage:
Primary or secondary riser cage (the primary riser cage is shown):
Removing and replacing a PCIe riser cage 51

Table of Contents

Other manuals for HP ProLiant DL560 Gen10