Specifications 87
Specifications
Environmental specifications
Specification Value
Temperature range*
Operating
10°C to 35°C (50°F to 95°F)
Shipping
-40°C to 70°C (-40°F to 158°F)
Maximum wet bulb temperature
28°C (82.4°F)
Relative humidity
(noncondensing)**
Operating
10% to 90%
Nonoperating
5% to 95%
* All temperature ratings shown are for sea level. An altitude derating of 1°C per 300 m (1.8°F per 1,000 ft) to 3,048
m (10,000 ft) is applicable. No direct sunlight allowed.
** Storage maximum humidity of 95% is based on a maximum temperature of 45°C (113°F). Altitude maximum for
storage corresponds to a pressure minimum of 70 kPa.
Mechanical specifications
Specification Value
Height
17.5 cm (6.88 in)
Depth
73.6 cm (29 in)
Width
44.4 cm (17.48 in)
Weight (maximum)
52 kg (115 lb)
Weight (no drives installed)
33 kg (73 lb)
Power supply specifications
Depending on installed options, the server is configured with one of the following power supplies:
HP 1200 W Common Slot Platinum Plus Hot-Plug Power Supply (94% efficiency) (on page 88)
HP 1500 W Common Slot Platinum Plus Hot-Plug Power Supply (94% efficiency) (on page 88)
For detailed power supply specifications, see the server QuickSpecs on the HP website
(http://www.hp.com/go/hpsc).