Table 2: RBSU settings on Gen8 servers with Intel processors
RBSU power
management options
Intelligent Provisioning Quick Configs settings
Balanced power and
performance
Minimum power usage Maximum performance
HPE Power Profile
Balanced Power and
Performance
Minimum Power Usage Maximum Performance
HPE Power Regulator
HPE Dynamic Power
Savings Mode
HPE Static Low Power
Mode
HPE Static High
Performance Mode
Intel QPI Link Power
Management
Enabled Enabled Disabled
Minimum Processor Idle
Power Core State
C6 State C6 State No C-states
Minimum Processor Idle
Power Package State
Package C6 (retention)
State
Package C6 (retention)
State
No Package State
Energy/Performance
Bias
Balanced Performance Power Savings Mode Maximum Performance
Maximum Memory Bus
Frequency
Auto Auto Auto
Channel Interleaving
Enabled Disabled Enabled
Maximum PCI Express
Speed
Maximum Supported PCIe Generation 1 Maximum Supported
iLO configuration
Use the iLO Configuration Utility to view and change iLO settings through Intelligent Provisioning, instead
of through the iLO web interface. For more information about iLO, see the iLO 4 User Guide.
You must configure iLO network settings to register the server with the Insight Remote Support
registration process.
When changing iLO settings, if the display is not as expected or an undefined error message is displayed,
press F5 to refresh the screen display. It is possible that the change was being made at the same time
through the iLO web interface.
Viewing iLO summary information
To view iLO summary information:
Procedure
1. In the Maintenance window, click iLO. The iLO Configuration Utility window is displayed.
2. Click Summary. The following information is displayed:
42 iLO configuration