Figure 48: HPE 3PAR StoreServ 7000 Storage Controller Node numbering, four-node Controller
Node Enclosure rear view
HPE 3PAR StoreServ 7000 Storage Controller Node ports
Figure 49: HPE 3PAR StoreServ 7000 Storage Controller Node ports
HPE 3PAR StoreServ 7000 Storage Controller Node ports
Port type Description
1 Ethernet ports (RC-1 &
MGMT)
RC-1: Onboard 1 Gb Ethernet port used for an HPE 3PAR Remote Copy or HPE
3PAR File Persona connection.
MGMT: Onboard 1 Gb Ethernet port used to connect to the network.
2 Fibre Channel ports Two onboard 16 Gb FC ports (FC-1, FC-2) used for the host server connection.
3 SAS ports Two onboard 12 Gb SAS ports (DP-1, DP-2) used for the expansion Drive
Enclosure connection.
4 Cluster Interconnect
Link
Cluster Interconnect Link ports (Intr0, Intr1) used only with 4-node storage
systems for the Controller Nodes 0 and 1 to Controller Nodes 2 and 3 connection.
5 PCIe host adapter slot PCIe slot used for optional host adapters (FC/CNA/NIC).
6 Console port Console port (MFG) is a serial connection for service procedures.
Component identification 115