cli% showpd -p -devtype NL -nodes 2,3
-----Size(MB)------ ----Ports----
Id CagePos Type RPM State Total Free A B Capacity(GB)
200 12:0:0 NL 7 normal 1848320 1766400 3:0:1* 2:0:1 2000
201 12:1:0 NL 7 normal 1848320 1766400 3:0:1 2:0:1* 2000
202 12:2:0 NL 7 normal 1848320 1765376 3:0:1* 2:0:1 2000
...
303 17:22:0 NL 7 normal 1848320 1765376 3:0:2 2:0:2* 2000
---------------------------------------------------------------------------
72 total 133079040 127172608
cli% showpd -p -devtype NL -nodes 0,1
cabling
Displays issues with cabling of Drive Enclosures (cages).
Cages cabled correctly to Controller Nodes
Cages cabled correctly to Drive Enclosure I/O Modules and ports
Cages with broken cables
Cable daisy-chain lengths balanced and supported length
Cable daisy-chain order
Cages with no PDs with primary path to Controller Nodes
NOTE:
To avoid any cabling errors, all Drive Enclosures must have at least one or more hard drive(s)
installed before powering on the enclosure.
Format of Possible cabling Exception Messages
Cabling <cageID> "Cabled to <nodelist>, remove a cable from <nodelist>"
Cabling <nodeID> "No cabling data for <nodeID>. Check status of <nodeID>"
Cabling <cageID> "Cage is connected to too many node ports (<portlist>)"
Cabling <cageID> "Cage has multiple paths to <portlist>, correct cabling"
Cabling <cageID> "I/O <moduleID> missing. Check status and cabling to <cageID> I/O <moduleID>"
Cabling <cageID> "Cage not connected to <nodeID>, move one connection from <nodeID> to <nodeID>"
Cabling <cageID> "Cage connected to different ports <node&portID> and <node&portID>"
Cabling <cageID> "Cage connected to non-paired nodes <node&portID> and <node&portID>"
Cabling <cageID> "Check connections or replace cable from (<cage,module,portID>) to (<cage,module,portID>) - failed
links"
Cabling <cageID> "Check connections or replace cable from (<cage,module,portID>) to (<cage,module,portID>) - links at
<speed>"
Cabling <nodepairID> "<node&portID> has <count> cages, <node&portID> has <count> cages"
Cabling <cageID> "Cable in (<cage,module,portID>) should be in (<cage,module,portID>)"
Cabling <cageID> "No PDs installed in cage, cabling check incomplete"
Cabling <cageID> "<node&portID> has <count> cages connected, Maximum is <count> (<cagelist>)"
Cabling <cageID> "<node&portID> should be cabled in the order: (<cagelist>)"
cabling Example 1
Component -Summary Description- Qty
Cabling Bad SAS connection 1
Component -Identifier- ----------------------------------------Detailed
Description-----------------------------------------
Cabling cage7 Check connections or replace cable from (cage6, I/O 0, DP-2) to (cage7, I/O 0, DP-1) - links at
6Gbps
64 cabling