Component Function
vlun
Displays VLUN issues
vv
Displays VV issues
alert
Displays any unresolved alerts and shows any alerts that would be seen by showalert -n .
Format of Possible alert Exception Messages
Alert <component> <alert_text>
alert Example
Component -Identifier- --------Detailed Description--------------------
Alert hw_cage:1 Cage 1 Degraded (Loop Offline)
Alert sw_cli 11 authentication failures in 120 secs
alert Suggested Action
View the full Alert output using the SSMC (GUI) or the 3PAR CLI command showalert -d .
ao
• Displays Adaptive Optimization issues
• Checks that all PD classes that exist on any node-pair are found on all node-pairs
Format of Possible ao Exception Messages
AO Nodes:<nodelist> "<PDclass> PDs need to be attached to this Node pair"
ao Example
Component ------Summary Description------- Qty
AO Node pairs with unmatched PD types 1
Component -Identifier- ------------Detailed Description------------
AO Nodes:0&1 NL PDs need to be attached to this Node pair
ao Suggestion Action
Use the following CLI commands to view PD distribution: showpd, showpd -p -devtype NL, showpd
-p -devtype NL -nodes 0,1, and showcage. In the example below, there are 72 NL PDs attached
to nodes 2&3, but none attached to nodes 0&1. Contact the Hewlett Packard Enterprise Support Center
to request support for moving NL PDs (and possibly cages) from nodes 2&3 to nodes 0&1 for your
system.