2010-10-22 10:35:36 PDT Created task.
2010-10-22 10:35:36 PDT Updated Executing "upgradecage -a -f" as 0:12109
2010-10-22 10:35:36 PDT Errored upgradecage: Invalid option: -f
vlun
Displays inactive Virtual LUNs (VLUNs) and those which have not been reported by the host agent
Reports VLUNs that have been configured but are not currently being exported to hosts or host-ports
Displays when too many VLUNs have been created
Format of Possible vlun Exception Messages
vlun vlun:(<vvID>, <lunID>, <hostname>)"Path to <wwn> is not is not seen by host"
vlun
vlun:(<vvID>, <lunID>, <hostname>) "Path to <wwn> is failed"
vlun host:<hostname> "Host <ident>(<type>):<connection> is not connected to a port"
vlun -- "<count> active VLUNs exceeds the supported limit of <max count>"
vlun Example
Component ---------Summary Description--------- Qty
vlun Hosts not connected to a port 1
Component -----Identifier----- ---------Detailed Description--------
vlun host:cs-wintec-test1 Host wwn:10000000C964121D is not connected to a
port
vlun
Suggested Action
Check the export status and port status for the VLUN and HOST with CLI commands such as:
showvlun
showvlun -pathsum
showhost
showhost -pathsum
showport
servicehost list
For example:
94 vlun