Power supplies
Cage firmware (is not current)
Reports if a servicecage operation has been started and has not ended.
Cages are supported for hardware platform
Format of Possible cage Exception Messages
Cage cage:<cageid> "Missing A loop" (or "Missing B loop")
Cage cage:<cageid>,mag:<magpos> "Magazine is <MAGSTATE>"
Cage cage:<cageid> "Power supply <X>'s fan is <FANSTATE>"
Cage cage:<cageid> "Power supply <X> is <PSSTATE>" (Degraded, Failed,
Not_Present)
Cage cage:<cageid> "Power supply <X>'s AC state is <PSSTATE>"
Cage cage:<cageid> "Cage is in "servicing" mode (Hot-Plug LED may be
illuminated)"
Cage cage:<cageid> "Firmware is not current"
Cage cage:<cageid> "Cage type <Model> is not supported on this platform"
Cage cage:<cageid> "Missing both A and B loops"
Cage cage:<cageid> "Cage state information is unavailable"
cage Example 1
Component -Summary Description- Qty
Cage Cages missing A loop 1
Component -Identifier- -Detailed Description--
Cage cage:1 Missing A loop
cage Suggested Action 1