cli% showport -sfp -ddm 0:1:1 1:1:1
--------------Port 0:1:1 DDM--------------
-Warning- --Alarm--
--Type-- Units Reading Low High Low High
Temp C 29 -5 85 -10 90
Voltage mV 3339 3000 3600 2900 3700
TX Bias mA 8 2 14 1 17
TX Power uW 478 158 562 125 631
RX Power uW 522 15 1000 10 1258
--------------Port 1:1:1 DDM--------------
-Warning- --Alarm--
--Type-- Units Reading Low High Low High
Temp C 33 -5 85 -10 90
Voltage mV 3332 3000 3600 2900 3700
TX Bias mA 7 2 14 1 17
TX Power uW 476 158 562 125 631
RX Power uW 98 15 1000 10 1258
port Example 2
Component -Summary Description- Qty
Port Missing SFPs 1
Component -Identifier- -Detailed Description--
Port port:0:3:1 SFP is missing
port Suggested Action 2
FC node-ports that normally contain SFPs will report an error if the SFP has been removed. The condition
can be checked using the showport -sfp command. In this example, the SFP in 1:1:1 has been
removed from the Adapter:
cli%
showport -sfp
N:S:P -State- -Manufacturer- MaxSpeed(Gbps) TXDisable TXFault RXLoss DDM
0:1:1 OK HP-F 8.5 No No No Yes
0:1:2 OK HP-F 8.5 No No Yes Yes
1:1:1 - - - - - - -
1:1:2 OK HP-F 8.5 No No Yes Yes
port Example 3
cli%
checkhealth -detail port
port Suggested Action 3
Check the state of the port with showport. If a port is offline, it was deliberately put in that state using the
controlport offline command. Offline ports might be restored using controlport rst.