Product Minimum firmware version
HPE ProLiant server system ROM
140
HPE Smart Array SR controllers 190
HPE Smart Array MR controllers 24230-0041
Installing an energy pack
Prerequisites
Before you perform this procedure, make sure that you have the following items available:
T-10 Torx screwdriver
The components included with the hardware option kit
Storage controller backup power cable (ships with the storage controller)
Make sure that a Smart Array P-class Gen10 controller is installed.
If you are installing the HPE Smart Storage Hybrid Capacitor,
verify that the system BIOS meets the minimum
firmware requirements.
Procedure
1.
Power down the server.
2.
Remove all power:
a.
Disconnect each power cord from the power source.
b.
Disconnect each power cord from the server.
3.
Do one of the following:
Extend the server from the rack.
Remove the server from the rack.
4.
Remove the access panel.
5.
Do one of the following:
Remove the air bale.
If installed, remove the 4LFF midplane drive cage.
6.
Remove the fan cage.
7. Install the energy pack.
Hardware options installation
106