Installing a rear 3LFF SAS/SATA drive cage
Before installing this option, the front bays must be fully populated with 12 LFF drives. High-performance fans must be
installed in all fan bays.
Prerequisites
Before you perform this procedure, make sure that you have the following items available:
• T-10 Torx screwdriver
• The components included with the hardware option kit
Procedure
1. Power down the server.
2. Remove all power:
a. Disconnect each power cord from the power source.
b. Disconnect each power cord from the server.
3.
Do one of the following:
•
Extend the server from the rack.
•
Remove the server from the rack.
4.
Remove the access panel.
5.
If installed, remove the secondary riser cage. The secondary riser cage is not supported with a three-bay LFF rear
configuration.
6. Remove the rear wall blank.
Hardware options installation
90