Booting up from flash solution
Data backup/redundancy
SubtopicsSubtopics
Installing an M.2 SSDInstalling an M.2 SSD
Installing an M.2 SSDInstalling an M.2 SSD
PrerequisitesPrerequisites
Use Intel VROC to configure M.2 SSDs.
If you are installing M.2 NVMe SSDs, the Intel VROC Standard license is required to support the RAID 0/1 configuration. For more
information on Intel VROC licenses, see the product QuickSpecs:
https://buy.hpe.com/us/en/p/1014705725https://buy.hpe.com/us/en/p/1014705725
Before beginning installation, make sure that the server is updated with the latest operating system firmware and drivers.
Before you perform this procedure, make sure that you have a Phillips No. 1 screwdriver available.
About this taskAbout this task
CAUTION:CAUTION: A discharge of static electricity from a finger or other conductor might damage system boards or other static-
sensitive devices. To prevent damage, observe antistatic precautions.
ProcedureProcedure
1. Back up all server data.
2. Power down the server.
3. Remove all power:
a. Disconnect each power cord from the power source.
b. Disconnect each power cord from the server.
4. Disconnect all peripheral cables from the server.
5. Do one of the following:
If the server is in tower mode, place the server on a flat, level surface with the access panel facing up .
If the server is in rack mode, remove the server from the rack.
6. Remove the access panel .
7. Remove the system air baffle.