EasyManua.ls Logo

HPE ProLiant ML110 Gen11

HPE ProLiant ML110 Gen11
217 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Installing the chassis intrusion detection switchInstalling the chassis intrusion detection switch
About this taskAbout this task
CAUTION:CAUTION: A discharge of static electricity from a finger or other conductor might damage system boards or other static-
sensitive devices. To prevent damage, observe antistatic precautions.
ProcedureProcedure
1. Power down the server.
2. Remove all power:
a. Disconnect each power cord from the power source.
b. Disconnect each power cord from the server.
3. Disconnect all peripheral cables from the server.
4. Do one of the following:
If the server is in tower mode, place the server on a flat, level surface with the access panel facing up .
If the server is in rack mode, remove the server from the rack.
5. Remove the access panel .
6. Remove the system air baffle.
7. Install the chassis intrusion detection switch:
a. Insert the switch tab into the chassis slot until the switch clicks into place.
b. Connect the switch cable.
HPE ProLiant ML110 Gen11 Server User Guide 160