EasyManua.ls Logo

HPE ProLiant ML110 Gen11

HPE ProLiant ML110 Gen11
217 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
ProcedureProcedure
1. Power down the server.
2. Remove all power:
a. Disconnect each power cord from the power source.
b. Disconnect each power cord from the server.
3. Disconnect all peripheral cables from the server.
4. Do one of the following:
If the server is in tower mode, place the server on a flat, level surface with the access panel facing up .
If the server is in rack mode, remove the server from the rack.
5. If you are installing the redundant system fan, remove the front bezel .
6. Remove the access panel .
7. Remove the system air baffle.
8. If installed, remove the riser cage.
9. Disconnect the default fan cable from the system board .
10. To remove the default system fan, do the following:
a. Release the fan cable from the cable clamp.
b. Remove the screws.
Retain the screws. These screws will be used to install the redundant system fan.
c. Detach the fan from the chassis.
HPE ProLiant ML110 Gen11 Server User Guide 108

Table of Contents

Related product manuals