CAUTION:CAUTION: A discharge of static electricity from a finger or other conductor might damage system boards or other static-
sensitive devices. To prevent damage, observe antistatic precautions.
ProcedureProcedure
1. Power down the server.
2. Remove all power:
a. Disconnect each power cord from the power source.
b. Disconnect each power cord from the server.
3. Disconnect all peripheral cables from the server.
4. Do one of the following:
If the server is in tower mode, place the server on a flat, level surface with the access panel facing up .
If the server is in rack mode, remove the server from the rack.
5. Remove the access panel .
6. Remove the system air baffle.
7. If the HPE NS204i-u Boot Device is installed, do the following:
a. Disconnect the HPE NS204i-u Boot Device cables from the system board.
b. Remove the HPE NS204i-u Boot Device.
HPE ProLiant ML110 Gen11 Server User Guide 134