12. Connect the signal and power cables to the boot device.
13. Install the HPE NS204i-u Boot Device cage assembly.
Make sure that the HPE NS204i-u Boot Device cage assembly and the release latch are locked on the chassis with the click sound.
14. Connect the boot device signal and power cables to the system board .
15. Make sure that all the system cables that are routed through the front cable channel are properly secured in the metal cable tabs and
cable clamps.
16. Install the system air baffle .
17. Install the access panel .
18. Do one of the following:
Orient the server back to tower mode.
Install the server into the rack.
19. Connect all peripheral cables to the server.
20. Connect the power cords:
a. Connect each power cord to the server.
b. Connect each power cord to the power source.
21. Power up the server.
ResultsResults
The installation is complete.
OCP NIC 3.0 adapter optionOCP NIC 3.0 adapter option
The server supports SFF dual-port and quad-port OCP NIC 3.0 adapter options with various interfaces and advanced interconnect features
for high-bandwidth applications.
HPE ProLiant ML110 Gen11 Server User Guide 154