Table 21: HPE SN6000B and SN3000B 16Gb FC switches environmental
requirements
Condition Acceptable range during operation Acceptable range during nonoperation
Ambient
temperature
0º to 40ºC (32º to 104ºF) -25º to 70ºC (-13º to 158ºF)
Humidity 10% to 85% RH noncondensing, at 40ºC
(104ºF)
10% to 90% RH noncondensing, at 70ºC
(158ºF)
Altitude 0 to 3 km (9,842 ft) above sea level 0 to 12 km (39,370 ft) above sea level
Shock 20 G, 6 ms, half-sine wave 33 G, 11 ms, half-sine wave, 3/e.g. Axis
Vibration 0.5 G sine, 0.4 gms random, 5–500 Hz 2.0 G sine, 1.1 gms random, 5–500 Hz
Airflow Maximum: 71.36 cubic m/h (42 cubic ft/m)
Nominal: 59.47 cubic m/h (35 cubic f/m)
N/A
Heat
dissipation
338 BTU/hr (32-port configuration)
375 BTU/hr (48-port configuration)
N/A
Table 22: StoreFabric SN4000B SAN Extension Switch environmental
requirements
Condition Acceptable range during operation Acceptable range during nonoperation
Ambient
temperature
0º to 40ºC (32º to 104ºF) -25º to 70ºC (-13º to 158ºF)
Humidity 5% to 93% RH noncondensing, at 40ºC
(104ºF)
10% to 95% RH noncondensing, at 70ºC
(158ºF)
Altitude 0 to 3 km (9,842 ft) above sea level 0 to 12 km (39,370 ft) above sea level
Shock 20 G, 11 ms, half-sine wave 20 G, 11 ms, half-sine wave, 3/e.g. Axis
Vibration 1.0 G sine, 0.5 gms random, 5–500 Hz 2.4 G sine, 1.1 gms random, 5–500 Hz
Airflow Maximum: 347 cubic m/h (204 cubic ft/m) N/A
Operating
noise
48.0 dBA N/A