CONSOLE
RESERVE FE0
RST
L1 L2 L3 N
A
RS485-0
BA
RS485-1 DI-0 DI-1
B
GE0
RX TX
GE1
MONITOR
RX TX
FE2 FE4
FE1 FE3 FE5
FE6
Power outage Survival
FE7
FE0 FE2 FE4
FE1 FE3 FE5
Ethernet interface of
the remote device
Step 4 Arrange the Ethernet cables to make them parallel, and then bundle them with cable ties. Use
diagonal pliers to cut off redundant cable ties.
Step 5 Remove the temporary labels from the Ethernet cables, and then attach formal labels 2 cm
away from the connectors at both ends.
----End
Follow-up Procedure
Check the following items after connecting Ethernet cables:
l Labels are correctly filled and securely attached to cables, with texts facing the same
direction.
l Cables and connectors are complete, intact, and tightly connected.
Huawei AR500&AR530&AR550 series Industrial Switch
Routers
Hardware Installation and Maintenance Guide
4 Installing an AR530 Series Industrial Switching Router
Issue 05 (2015-12-01) Huawei Proprietary and Confidential
Copyright © Huawei Technologies Co., Ltd.
71