Step 4 Remove the dust caps from the fiber connectors. Connect one end of the optical fiber to the
optical module and the other end to the remote device.
NOTE
Connect the receive and transmit ends of the fiber connector according to the identifiers on receive and
transmit bores of the optical module. Do not connect the two ends reversely.
5VZOIGRLOHKX
8KSUZKUVZOIGROTZKXLGIK
Step 5 Arrange the optical fibers to make them parallel and bundle them with fiber binding tape at an
interval of 150 mm to 300 mm.
Step 6 Replace all the temporary labels with formal labels on the optical fibers.
----End
5.6.5 Connecting Boolean Output Cables
Context
DANGER
To avoid electric shock, do not connect power cables while the power is on.
Huawei AR500&AR530&AR550 series Industrial Switch
Routers
Hardware Installation and Maintenance Guide
5 Installing an AR550 Series Industrial Switching Router
Issue 05 (2015-12-01) Huawei Proprietary and Confidential
Copyright © Huawei Technologies Co., Ltd.
107