5.5 Storage
5.5.1 Drive
Congurations
Table 5-8 Drive congurations
Conguration
Maximum Front Drives Drive Management
Mode
8 x 2.5" SAS/SATA drive
conguration
8
● Slots 0 to 7 support
only SAS/SATA drives.
1 x RAID controller card
24 x 2.5" (16 x SAS/SATA
+ 8 x NVMe) drive
conguration
24
● Slots 0 to 3 and slots
20 to 23 support only
NVMe drives.
● Slots 4 to 19 support
only SAS/SATA drives.
1 x RAID controller card
+ 2 x NVMe adapter
25 x 2.5" SAS/SATA drive
conguration
25
● Slots 0 to 24 support
only SAS/SATA drives.
1 x RAID controller card
● Contact your local Huawei sales representative or use the Computing
Product Compatibility Checker to determine the components to be used.
5.5.2 Drive Numbering
● 8 x 2.5" SAS/SATA drive conguration
Huawei FusionServer Pro 2488 V5 Server
Technical White Paper 5 Hardware Description
Issue 11 (2020-09-03) Copyright © Huawei Technologies Co., Ltd. 30