Conguratio
n
Max. 30°C
(86°F)
Max. 35°C
(95°F)
Max. 40°C
(104°F)
Max. 45°C
(113°F)
24 x 2.5" (16
x SAS/SATA
+ 8 x NVMe)
drive
conguration
All options
supported
P4/T4 GPU
cards are
not
supported.
Options
supported:
processors
of up to
140 W
Options
not
supported:
NVMe
SSD
cards in
slots 1
to 6
GPU
cards
Not
supported
25 x 2.5" SAS/
SATA drive
conguration
All options
supported
P4/T4 GPU
cards are
not
supported.
Options
supported:
processors
of up to
165 W
Options
not
supported:
NVMe
SSD
cards in
slots 1
to 6
GPU
cards
Not
supported
NO TE
If a single fan is faulty, the maximum operating temperature is 5°C (9°F) lower than the
rated value.
A.3 RAS Features
The server supports a variety of Reliability, Availability, and Serviceability (RAS)
features. You can congure these features for better RAS.
For details about how to
congure RAS features, see Huawei Server Purley
Platform BIOS Parameter Reference.