Category Specications
Security features Power-on password
Administrator password
TCM (only in China)/TPM
Secure boot
Front bezel (optional)
6.2 Environmental Specications
Table 6-2 Environmental specications
Category Specications
Temperature Operating temperature: 5°C to 45°C (41°F to 113°F)
(ASHRAE Classes A2 to A4 compliant)
Storage temperature (≤ 72 hours): –40°C to +65°C
(–40°F to +149°F)
Long-term storage temperature (> 72 hours): 21°C
to 27°C (69.8°F to 80.6°F)
Maximum temperature change rate: 20°C/h (36°F/h)
NOTE
The highest operating temperature varies depending on the
server
conguration. For details, see A.2 Operating
Temperature Limitations.
Relative humidity (RH,
non-condensing)
Operating humidity: 8% to 90%
Storage humidity (≤ 72 hours): 5% to 95%
Long-term storage humidity (> 72 hours): 30% to
69%
Maximum change rate: 20%/h
Air volume ≥ 198 cubic feet per minute (CFM)