EasyManua.ls Logo

Huawei FusionServer Pro 2488 V5 - RAID Controller Card

Huawei FusionServer Pro 2488 V5
84 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Activity Indicator
(Green)
Fault Indicator
(Yellow)
Description
Steady on Blinking at 1 Hz The drive is being located.
Blinking at 1 Hz Blinking at 1 Hz The data on the secondary drive is
being rebuilt.
O Steady on A member drive in the RAID array is
removed.
Steady on Steady on The drive is faulty.
NVMe Drive Indicators
Figure 5-22 NVMe drive indicators
Table 5-10 Description of NVMe drive indicators (only orderly hot swap
supported)
Activity Indicator
(Green)
Fault Indicator
(Yellow)
Description
O O The NVMe drive cannot be detected.
Steady on O The NVMe drive is working properly.
Blinking at 2 Hz O Data is being read from or written to
the NVMe drive.
O Blinking at 2 Hz The NVMe drive is being located or
hot-swapped.
O Blinking at 0.5 Hz The hot removal process is complete,
and the NVMe drive is removable.
Steady on/O Steady on The NVMe drive is faulty.
5.5.4 RAID Controller Card
The RAID controller card supports RAID conguration, RAID level migration, and
drive roaming.
Huawei FusionServer Pro 2488 V5 Server
Technical White Paper 5 Hardware Description
Issue 11 (2020-09-03) Copyright © Huawei Technologies Co., Ltd. 32