Callout No. Description
4 Year and month (two characters).
● The rst character indicates the year.
– Digits 1 to 9 indicate years 2001 to 2009, respectively.
– Letters A to H indicate years 2010 to 2017, respectively.
– Letters J to N indicate years 2018 to 2022, respectively.
– Letters P to Y indicate years 2023 to 2032, respectively.
NOTE
The years from 2010 are represented by uppercase letters excluding
I, O, and Z because the three letters are similar to digits 1, 0, and 2.
● The second character indicates the month.
– Digits 1 to 9 indicate January to September, respectively.
– Letters A to C indicate October to December, respectively.
5 Sequence number (six characters).
6 RoHS compliance (one character). Y indicates RoHS compliant.
7 Internal model, that is, product name.
A.2 Operating Temperature Limitations
Table A-2 Operating temperature limitations
Conguratio
n
Max. 30°C (86°F) Max. 35°C (95°F) Max. 40°C (104°F)
Single RAID
conguration
(with built-in
drives)
● Platinum
8180/8168/8280
/8270/8268 and
Gold
6154/6151/6254
processors not
supported
Options not
supported:
● Platinum
8180/8168/8280
/8270/8268 and
Gold
6154/6151/6254
processors
● I/O modules 1
and 2
congured with
drives
● I/O module 3
congured with
NVMe drives
● Built-in drives
● PCIe SSD cards
Options supported:
● Platinum
8153/8253, Gold
6152/6140/6126
/5118/5218, and
other processors
lower than 105
W
Options not
supported:
● I/O modules 1
and 2
congured with
drives
● I/O module 3
congured with
NVMe drives
● PCIe SSD cards
Huawei FusionServer Pro 5288 V5 Server
Technical White Paper A Appendix
Issue 10 (2020-12-15) Copyright © Huawei Technologies Co., Ltd. 81